Journal Search Engine
Download PDF Export Citation Korean Bibliography PMC Previewer
ISSN : 1738-4125(Print)
ISSN : 2287-7509(Online)
Journal of Odor and Indoor Environment Vol.6 No.2 pp.135-148
DOI :

문화재 보존환경 대상 물리적 환경인자 및 유해화학오염물질 선정에 관한 연구

이철민*, 김윤신, 노영만
한양대학교 환경 및 산업의학연구소

Identification of Hazardous Physical Factors and Chemical Pollutants in Museum

Cheol Min Lee*
Institute of Environmental and Industrial Medicine, Hanyang University

Abstract

The purpose of this study is to identify hazardous physical factors and chemical air pollutants inconservation museum in order to protect the cultural heritage. For this, we collected and re-analyzed thearticles that were published from 2006 to 2007 by National Research Institute of Cultural Heritage fortemperature, relative humidity and the level of pollutants (PM10, CO2, HCHO, CO, NO2, Rn, TVOCs, O3, SO2)in exhibition hall and storage in museum. The pooled average level of temperature at exhibition hall andstorage in museum was 23.5±1.4℃ and 20.6±1.1℃, respectively. The range of temperature variation was5.4℃ for exhibition hall and 4.5℃ for storage. The pooled average concentration of TVOCs in exhibition halland storage in museum was 493.6±125.6㎍/m3 and 788.9±157.5㎍/m3, respectively. These exceeded 400㎍/m3 which is the guideline of national law for the Korean Ministry of Public Administration and Security(KMOPAS). Other surveyed pollutants were as per the guidelines of the national law for the Korean Ministryof Environment (KMOE) and the KMOPAS. Through the consideration of the physical and chemical propertiesand the result of meta-analysis for thermal environment and surveyed temperature, humidity, PM10, NO2, SO2,O3, TVOCs, and HCHO were the identified hazardous physical factors and chemical pollutants at exhibitionhalls and storages in museum.

A9RCA19.pdf720.5KB

Reference